Make it VERY clear when nomulus shell is on PROD
We don't want people to accidentally run commands on prod thinking they were on Alpha / Sandbox. To do that - we add 2 safeguards: 1) when on prod, the shell has a strong RED "PRODUCTION" in the commandline, while on alpha/sandbox it's green. 2) if a prod shell is idle for > 1h, it exits. So don't accidentally use a prod shell from a long time ago. ------------- Created by MOE: https://github.com/google/moe MOE_MIGRATED_REVID=191931731
This commit is contained in:
parent
7bf0b059a6
commit
013558c814
3 changed files with 108 additions and 18 deletions
|
@ -19,11 +19,15 @@ import static com.google.common.collect.ImmutableList.toImmutableList;
|
|||
import static java.nio.charset.StandardCharsets.US_ASCII;
|
||||
|
||||
import com.beust.jcommander.JCommander;
|
||||
import com.beust.jcommander.Parameter;
|
||||
import com.beust.jcommander.ParameterDescription;
|
||||
import com.beust.jcommander.Parameters;
|
||||
import com.google.common.annotations.VisibleForTesting;
|
||||
import com.google.common.base.Ascii;
|
||||
import com.google.common.collect.ImmutableList;
|
||||
import com.google.common.collect.ImmutableTable;
|
||||
import google.registry.util.Clock;
|
||||
import google.registry.util.SystemClock;
|
||||
import java.io.BufferedReader;
|
||||
import java.io.File;
|
||||
import java.io.IOException;
|
||||
|
@ -41,6 +45,8 @@ import jline.ConsoleReader;
|
|||
import jline.ConsoleReaderInputStream;
|
||||
import jline.FileNameCompletor;
|
||||
import jline.History;
|
||||
import org.joda.time.DateTime;
|
||||
import org.joda.time.Duration;
|
||||
|
||||
/**
|
||||
* Implements a tiny shell interpreter for the nomulus tool.
|
||||
|
@ -52,10 +58,22 @@ import jline.History;
|
|||
public class ShellCommand implements Command {
|
||||
|
||||
private static final String HISTORY_FILE = ".nomulus_history";
|
||||
private static final String RESET = "\u001b[0m";
|
||||
private static final String NON_ALERT_COLOR = "\u001b[32m"; // green foreground
|
||||
private static final String ALERT_COLOR = "\u001b[1;41;97m"; // red background
|
||||
private static final Duration IDLE_THRESHOLD = Duration.standardHours(1);
|
||||
|
||||
private final CommandRunner runner;
|
||||
private final BufferedReader lineReader;
|
||||
private final ConsoleReader consoleReader;
|
||||
private final Clock clock;
|
||||
|
||||
@Parameter(
|
||||
names = {"--dont_exit_on_idle"},
|
||||
description =
|
||||
"Prevents the shell from exiting on PROD after the 1 hour idle delay. "
|
||||
+ "Will instead warn you and require re-running the command.")
|
||||
boolean dontExitOnIdle = false;
|
||||
|
||||
public ShellCommand(CommandRunner runner) throws IOException {
|
||||
this.runner = runner;
|
||||
|
@ -71,20 +89,29 @@ public class ShellCommand implements Command {
|
|||
consoleReader = null;
|
||||
}
|
||||
this.lineReader = new BufferedReader(new InputStreamReader(in, US_ASCII));
|
||||
this.clock = new SystemClock();
|
||||
}
|
||||
|
||||
@VisibleForTesting
|
||||
ShellCommand(InputStream in, CommandRunner runner) {
|
||||
ShellCommand(BufferedReader bufferedReader, Clock clock, CommandRunner runner) {
|
||||
this.runner = runner;
|
||||
this.lineReader = new BufferedReader(new InputStreamReader(in, US_ASCII));
|
||||
this.lineReader = bufferedReader;
|
||||
this.clock = clock;
|
||||
this.consoleReader = null;
|
||||
}
|
||||
|
||||
public ShellCommand setPrompt(String prompt) {
|
||||
if (consoleReader != null) {
|
||||
consoleReader.setDefaultPrompt(prompt);
|
||||
private void setPrompt(RegistryToolEnvironment environment, boolean alert) {
|
||||
if (consoleReader == null) {
|
||||
return;
|
||||
}
|
||||
if (alert) {
|
||||
consoleReader.setDefaultPrompt(
|
||||
String.format("nom@%s%s%s > ", ALERT_COLOR, environment, RESET));
|
||||
} else {
|
||||
consoleReader.setDefaultPrompt(
|
||||
String.format(
|
||||
"nom@%s%s%s > ", NON_ALERT_COLOR, Ascii.toLowerCase(environment.toString()), RESET));
|
||||
}
|
||||
return this;
|
||||
}
|
||||
|
||||
public ShellCommand buildCompletions(JCommander jcommander) {
|
||||
|
@ -101,8 +128,21 @@ public class ShellCommand implements Command {
|
|||
/** Run the shell until the user presses "Ctrl-D". */
|
||||
@Override
|
||||
public void run() {
|
||||
// On Production we want to be extra careful - to prevent accidental use.
|
||||
boolean beExtraCareful = (RegistryToolEnvironment.get() == RegistryToolEnvironment.PRODUCTION);
|
||||
setPrompt(RegistryToolEnvironment.get(), beExtraCareful);
|
||||
String line;
|
||||
DateTime lastTime = clock.nowUtc();
|
||||
while ((line = getLine()) != null) {
|
||||
// Make sure we're not idle for too long. Only relevant when we're "extra careful"
|
||||
if (!dontExitOnIdle
|
||||
&& beExtraCareful
|
||||
&& lastTime.plus(IDLE_THRESHOLD).isBefore(clock.nowUtc())) {
|
||||
throw new RuntimeException(
|
||||
"Been idle for too long, while in 'extra careful' mode. "
|
||||
+ "The last command was saved in history. Please rerun the shell and try again.");
|
||||
}
|
||||
lastTime = clock.nowUtc();
|
||||
String[] lineArgs = parseCommand(line);
|
||||
if (lineArgs.length == 0) {
|
||||
continue;
|
||||
|
|